Gloves
Liquidborne Particle Counts
IEST-RP-CC005.4:
0.5 µm and greater: 0.5, 1, 2, 5, 10, and 20
0.3 µm and greater: 0.3, 0.5, 1, 2, 5, 10, and 20
0.2 µm and greater: 0.2, 0.3, 0.5, 1, 2, 5, 10, and 20
Ion Extractables
IEST-RP-CC005.4:
Anion Extractables (Br-, Cl-, F-, NO2-, NO3-, PO4-, SO4-)
Cation Extractables (NH4+, Ca++, Li+, Mg++, K+, Na+)
Cation Extractables (Cu, Co, Fe, Mn, Ni, Zn)
Cations including NH4+ and Trace Metals (30 elements)
NVR
IEST-RP-CC005.4
Liquidborne Particle Counts
Helmke Drum and custom protocols
FTIR
FTIR Analysis for Silicone
Test Methods
-
Liquidborne Particle Count
Ultrapure Water Extraction and enumeration by Automatic Laser Particle Counter and/or Microscopy
-
Anions and Cations
Ultrapure Water Extraction and Ion Chromatography
-
Nonvolatile Residues (NVR)
Isopropyl alcohol and Ultrapure Water Extraction and gravimetric quantitation and spectroscopic identification of residue
-
Silicone
Identification and quantitation by FTIR
We follow IEST Recommended Practices, industry standards, and custom protocols.