Wipers
Liquidborne Particle Counts
IEST-RP-CC004.3: Biaxial Shake Test in DI Water, Enumeration Technique: APC
IEST-RP-CC004.4: Orbital Shake Test in DI Water, Enumeration Technique: APC
0.5 µm and greater: 0.5, 1, 2, 5, 10, and 20
0.3 µm and greater: 0.3, 0.5, 1, 2, 5, 10, and 20
0.2 µm and greater: 0.2, 0.3, 0.5, 1, 2, 5, 10, and 20
Fibers and Particle Fragments >100µm
IEST-RP-CC004.3: Biaxial Shake Test, Enumeration Technique: Microscopy
IEST-RP-CC004.4: Orbital Shake Test, Enumeration Technique: Microscopy
Ion Extractables
IEST-RP-CC004.4: Anion Extractables
(Br-, Cl-, F-, NO2-, NO3-, PO4-, SO4-)
IEST-RP-CC004.4: Cation Extractables
(NH4+, Ca++, Li+, Mg++, K+, Na+)
IEST-RP-CC004.4: Cation Extractables
(Cu, Co, Fe, Mn, Ni, Zn)
IEST-RP-CC004.4: Cations including NH4+and Trace Metals (30 elements)
NVR
IEST-RP-CC004.4
DI Water, IPA
Sorbency (Capacity and Rate)
IEST-RP-CC004.4
FTIR
FTIR Analysis for Silicone and Non Volatile Residues (NVR)
Test Methods
-
Liquidborne Particle Count
Ultrapure Water Extraction and enumeration by Automatic Laser Particle Counter and/or Microscopy
-
Anions and Cations
Ultrapure Water Extraction and Ion Chromatography
-
Nonvolatile Residues (NVR)
Isopropyl alcohol and Ultrapure Water Extraction and gravimetric quantitation and spectroscopic identification of residue
-
Silicone
Identification and quantitation by FTIR
We follow IEST Recommended Practices, industry standards, and custom protocols.